DAB CM and CM-G: In-Line Circulation Pumps for Large Chilled Water, Hot Water and Solar Loops
When a building’s water loop grows large, small wet rotor circulators run out of capacity. A shopping plaza’s chilled water header, a hospital’s hot water ring or a factory’s process loop can need hundreds of cubic metres of water per hour. The DAB CM and CM-G are designed for that scale. They are in-line pumps from DAB Pumps of Italy, made for air-conditioning, heating, water recirculation in the presence of solar thermal panels (solar collectors) and the circulation of hot water in commercial building service.
In an in-line pump, the inlet and outlet sit on the same axis, so the pump drops straight into a pipe run with no change of direction. The CM and CM-G have flanged in-line ports, with the pump body, motor support and fan cover in cast iron, and an impeller in cast iron or technopolymer depending on the model. All versions have a four-pole motor. The CM-G is the version equipped with a coupling, and the CM is the standard single pump. AY Internationals supplies the original DAB CM and CM-G and helps you size them for your project.
Important: an in-line circulation pump moves water around a loop. It does not lift water from a tank or well, and it is not a pressure booster for household taps. For those jobs, see the pumps linked below.
Features and Benefits
- Very wide flow range, 1.2 to 420 m³/h: One family covers everything from a small plant room to a large commercial building, so you can choose the model that fits your loop.
- Head up to 41 metres: Enough to push water through long pipe runs, many coils and high buildings.
- Liquid temperature from -10°C to +140°C: Handles both chilled water for AC and very hot water. DAB lists the upper limit as +140°C, with +130°C on the smaller DN40 and DN50 sizes.
- Working pressure up to 16 bar: Suited to the pressurized closed circuits used in tall buildings.
- In-line flanged ports: Inlet and outlet sit on the same axis, so the pump fits directly into straight pipework and uses less plant room space than an end-suction pump.
- Cast iron pump body, motor support and fan cover: A rigid, durable build for plant rooms that run for long hours.
- Cast iron or technopolymer impeller: Chosen by model to suit the duty.
- Four-pole motor: Runs at a lower speed than a two-pole motor, which suits continuous circulation duty. Motor sizes start at 0.25 kW and go well above 20 kW.
- IP55 protection, up to 40°C room temperature: Sealed against dust and water jets, suited to plant rooms.
- CM-G with coupling: A coupled version is available when you want that construction.
- Solar thermal compatible: DAB designs the family for water recirculation in the presence of solar collectors, and the circulation of hot water in commercial buildings.
- Handles glycol up to 30%: Useful in antifreeze or solar loops, according to DAB’s technical data.
Note: install the pump horizontally or vertically, but always with the motor above the pump. For motor powers above 7.5 kW, vertical installation only is allowed. The pump should be filled and bled before starting, and the motor must be protected against overload in line with local regulations. Our engineers will specify the right model code, flange size and starter for your system.
CM or Another DAB In-Line Pump?
DAB’s CM and CM-G sit at the larger end of its in-line range. For smaller loops, see the DAB ALM and ALP, or the wet rotor DAB BPH and BMH circulators. DAB also makes the family in other versions: the CM2 and CP for different hydraulic duties, and the DCM twin with two pumps in one body. For other in-line sizes, look at the DAB KLM and KLP. If you need to boost pressure for taps or lift water from a tank, look at the DAB Jet or the DAB Esybox Mini³.
Why Buy Your DAB CM or CM-G from AY Internationals
- Authorized DAB dealer: AY Internationals is one of the authorized dealers of DAB in Pakistan. See our DAB authorization documents.
- Genuine stock with official warranty support: Every pump we supply is original DAB, with model codes matching the box and nameplate. Warranty terms are given in writing, and we handle support directly.
- ISO 9001:2015 certified: Our supply, installation and service processes follow an ISO 9001:2015 certified quality management system.
- Free technical guidance and site survey: Share your system type, flow, head and flange size, and our engineers will recommend the right model at no cost.
- Installation and after-sales service: We install, test and commission pumps and support them with spare parts and service. See our services.
- Lahore office, nationwide delivery: Whether you need a DAB supplier in Lahore or a DAB distributor in Pakistan that delivers to your city or project, we ship across the country.
- Experience since 2015: Our pumps serve homes, hotels, hospitals and malls. Browse our completed projects.
Official DAB Documentation
Download DAB’s official documents for installation instructions, wiring and compliance details:
- CM-G – Instruction Manual
- CM – Instruction Manual
- CM, CM-G – Quick Guide
- CM, CM-G – Declaration of conformity CE
- DAB CM, CM-G on the official DAB website
Frequently Asked Questions
What are the DAB CM and CM-G pumps used for?
They are in-line pumps designed for conditioning, heating, water recirculation in the presence of solar thermal panels (solar collectors) and the circulation of hot water in commercial building service. They cover flows from 1.2 to 420 m³/h and head up to 41 metres.
What is the difference between the CM and the CM-G?
Both are single in-line pumps with a four-pole motor, a cast iron pump body and flanged ports. The CM-G is the version equipped with a coupling, while the CM is the standard version.
What liquid temperature can the DAB CM handle?
DAB lists a liquid temperature range from -10°C to +140°C, with a maximum working pressure of 16 bar. The smaller DN40 and DN50 sizes are limited to +130°C, and glycol content is limited to 30% unless DAB technical support advises otherwise.
How should the DAB CM be installed?
It can be installed in a horizontal or vertical position as long as the motor is always above the pump. For motors above 7.5 kW, installation must be vertical. The pump must be filled and bled before starting, and the motor needs overload protection.
Where can I buy a genuine DAB CM in Lahore?
AY Internationals is an authorized DAB dealer in Lahore with delivery across Pakistan. Our DAB authorization documents are on our website, and you can WhatsApp +92 300-8482031 for the price.
Does the DAB CM come with a warranty?
Yes. Every genuine DAB CM bought from AY Internationals includes official warranty support, with warranty terms given in writing.
Get the Right In-Line Pump for Your Plant
Share your system type, required flow and head, liquid temperature and flange size, and we’ll recommend the right CM or CM-G model with a quotation. Learn more about us as a DAB pumps dealer in Pakistan, or contact us directly:
WhatsApp for Price | Get a Free Quote | Call +92 300-8482031









Reviews
There are no reviews yet.